| Characteristics |
Test
Method |
Specifications |
| High Temperature Storage/Dry Heat |
The specimen shall be subjected to 125± 2oC
for 1000 hours in a thermostatic bath with out load and then stored at room temperature
and humidity for 1 to 2 hors. Thereafter, change of Vc shall be measured. |
¡µVcmA/VcmA¡Ø ±5% |
| Damp Heat/Humidity (Steady State) |
The specimen shall be subjected to 40± 20oC,
90 to 95% RH for 1000 hours without load and then stored at room temperature and humidity
for one to two hours. Thereafter, the change of Vc shall be measured. |
| Temperature Cycle |
| The temperature cycle shown below shall be
repeated five times and then stored at room temperature and humidity for 1 to 2 hours. The
change of Vc and mechanical damage shall be examined. |
| Step |
Temperature(oC) |
Period(minutes) |
| 1 |
-40±3 |
30±3 |
| 2 |
Room temperature |
15±3 |
| 3 |
125±2 |
30±3 |
| 4 |
Room temperature |
15±3 |
|
| High Temperature Load/Dry Heat Load |
After being continuously applied the Maximum
Allowable Voltage at 85 ± 2oC for 1000 hours, the specimen shall be stored at room
temperature and humidity for 1 to 2 hours. Thereafter, the change of Vc shall be measured. |
¡µVcmA/VcmA¡Ø ±10% |
| Damp Heat Load Humidty Load |
The specimen shall be subjected to 40±2oC,
90 to 95% RH and the Maximum Allowable Voltage for 1000 hours and then stored at room
temperature and humidity for 1 to 2 hours, Thereafter, the change of Vc shall be measured. |
¡µVcmA/VcmA¡Ø ±10% |
| Low Temperature Storage/Cold |
The specimen shall be subjected to -40±2oC
without load for 1000 hours and then stored at room temperature for 1 to 2 hours.
Thereafter, the change of Vc shall be measured. |
¡µVcmA/VcmA¡Ø ±5% |